  • System for UHV Temperature Programmed Desorption (TPD) Studies

    TPD Workstation - Hiden Analytical Ltd.

    The Hiden TPD Workstation is a complete experimental system for UHV temperature programmed desorption (TPD) studies. The triple filter mass analyser is configured with a cooled shroud giving the analyser optimum sensitivity with minimum background contributions to desorption products from the sample. A fast sample load lock with sample transfer mechanism is included to provide for rapid sample change. The TPD Workstation features a multiport UHV chamber with heated sample stage coupled to a high precision triple filter analyser with digital pulse ion counting detector for ultimate sensitivity and time resolution.

  • Walk-In Solar Spectrum Test Chamber

    ACMAS Technologies Pvt. Ltd.

    WEIBER walk in Solar Spectrum Test Chambers are one of solutions to be utilized in large scale PV testing program. We offer customized as well as standard multidimensional test program for PV modules in reasonable prices. This system delivers the weathering stress representative of long term outdoor exposure.Our flexible system can be designed according to our test requirements, to suit environmental test conditions like volume, temperature, humidity solar radiation intensity and other measuring instruments. It is also called Walk in Solar Radiation Test Chamber.WEIBER solar test system are recognized for superior solar simulation environmental Testing, evaluating outdoor use product reliability, quality & safety. This technology allows for very high concentrations of UV energy without excessive heating of test samples. Custom mounting and cooling can be added depending upon specific material exposure requirements. MHGs (metal halide global lamps) are used as radiation source. Solar spectrum chamber also known as Walk in Solar Simulation Test Chamber

  • AC Loadbanks

    Hillstone Products Ltd.

    Regular load bank testing of generators provides an essential health check service to prevent diesel engine failure due to wet stacking. Wet stacking occurs due to under loading of the genset which results in wet un-burned fuel building up in the engine. This fuel build up will over time line the combustion chamber cylinders and cause a reduction of the engines rating and efficiency which will ultimately cause premature failure of the generator. Running the generator on load of 50% - 100% of the genset rating will allow the engine to reach the recommend operating temperature, which will burn off the choke deposits.

  • Solar Radiation Testing

    Keystone Compliance

    Solar radiation test setups are custom designed for each test setup. Solar arrays can be provided for small or large test articles. Arrays are designed and calibrated prior to placement of the test article. Testing takes place within any of our various temperature chambers. Solar arrays are microprocessor controlled and are capable of delivering greater than the 1,200 watts per meter squared as required by most commonly used test specifications. Custom programs can be designed to simulate real world test cycles of sunrise to sunset. Keystone Compliance offers Solar radiation testing for heating effects only.

  • Vapor Sorption Analysis

    TA Instruments

    Vapor Sorption Analysis is a technique in which a sample is subjected to varying conditions of humidity and temperature, and the response of the sample is measured gravimetrically. Understanding the effects of water content on structure and properties is critical in the development, processing and end use of a broad spectrum of materials. TA Instruments offers the most sensitive, versatile, and productive moisture sorption analyzers on the market. The Discovery SA combines a high-sensitivity thermobalance, innovative humidity control chamber, and reliable autosampler. Innovative technology combined with our unparalleled reputation for service and support make TA Instruments the clear choice of scientists worldwide for vapor sorption studies.

  • Chamber/Pyroelectric Task

    Radiant Technologies, Inc.

    Radiant's Chamber/Pyroelectric Task sets the sample to a series of temperatures by performingGPIB control of an external thermal device. At each temperature it captures the sample’s polarization response and/or small-signalcapacitance. These are combined to calculate the pyroelectric coef­ficient.  The Pyroelectric Task is to be used with a Radiant Test System and a Linkam Stage (-196C to 600C), Thermal Chambers, Hot Chucks, or a Furnace to automatically measure the Pulse Polarization response and Small Signal Capacitance of a Pyroelectric material that is being heated and/or cooled.  Radiant's Pyroelectric measurement Task can be added to Vision at additional cost.  This measurement suite fully characterizes the pyroelectric charge (polarization) response of the sample under test.  The Pyroelectric Task suite controls various thermal controllers such as Quantum Design, Lake Shore, Delta Design, and many others. Detailed Listing of Thermal Controllers Registered in Vision.   The Chamber/Pyroelectric Task is quoted upon request.

  • Electrical Probe Systems

    Instec, Inc.

    INSTEC's Probe Systems offer an integrated solution for performing component-level electrical measurements over a wide temperature range.Compact Mini Probe Stages enable an existing inspection microscope or optical test setup to be converted easily into a precision temperature-controlled semiconductor testing and qualification station.Analytical probe stations are fully featured industry-standard platforms for all modern probing applications and testing.Benchtop Probe Stations provide the user with four independent electrical probes with X,Y,Z micropositioning for precise placement without opening the sample chamber.​Highly configurable probe systems meet a range of requirements for atmospheric and temperature control, sample areas, and electrical measurements.

  • Multiplex Optical Maintenance Meter

    LS280 - Lisun Electronics Inc.

    LS280 is used to measure optical maintenance factor for high power LEDs, LED module, LED bulb or other LED luminaries. It is the important measuring equipment for performing the reliability of illuminants. • Freely set the time interval and time extent for automatic measurement • LCD Display, connect with PC via RS232 and English version software. • The test results can export Excel or PDF format and easy to compare. It can be saved by LS280 software or by USB directly. • The engineer can do LED life analysis based on the LS280 test results. • LS280 worked with High Power LED Aging Test (LS600), Multiplex LED Temperature Test (TMP-8/TMP-16) and High and Low Temperature & Humidity Chamber (GDJS-*B), it can do Flux VS Temperature VS Time, which is a perfect instrument system to meet LM-80 request.

  • Enerchron® 2.0 Test Management Software

    NH Research, Inc.

    Enerchron 2.0 test management software is a software suite ideally suited for test applications that yield extensive data over an extended period of time such as battery cycling and evaluation. It allows the creation of complex, dynamic test sequences without requiring the skills of a programmer. In addition to real-time viewing during execution, measurements are automatically archived for review and analysis after testing has been completed. Enerchron is available with NH Research’s Regenerative Battery Test System (Model 9200) or can be used to control additional Battery Test Systems, NHR air-cooled electronic loads, power supplies, temperature chambers, and data acquisition devices that measure temperature and pressure.

  • Hybridization Oven

    REXMED ROV-201 - REXMED Industries Co., Ltd.

    MOD. ROV-201, AC 110/230V, Plug type: , Hybridization oven, HS CODE: 841780, UNCCS CODE: 484352, UMDNS CODE: 14410, Main construction: powder coated steel and SS304, Controller: Microprocessor based PID controller, water proof keypad with timer, ˚C/PV and ˚C/SV display and setting, Timer: 9999/min, 9999/hr, Timer has DELAY_ON and DELAY_OFF function and at the end of operation audio and visual warning, Working range: Ambient +5˚C~85˚C, Stability at 37˚C: ±0.1˚C, Sensor: PT 100Ω, Temperature audio and visual warning for AL-H and AL-L and OFS correction setting, Heater: 1.2KW, Shaking timer: 999/min, 999/hr, shaking timer can be set in second, minute or hour function and at the end of operation audio and visual warning, Motor: Noiseless powerful brushless induction motor 15W, Rotation: 5~60rpm adjustable, Rotator: for 8pcs(optional), Orbital: 20~250rpm adjustable, Platform: L30 X W20cm, Chamber: L35 X W25 X H42.5cm, Capacity: 37.2L, chamber with glass viewing window, Optional: Rotator for 8pcs X 1set

  • Chamber Controller Software

    Crystal instruments

    EDC (Embedded Device Control) is specifically designed software for Sentek chamber system controllers running Temperature and Humidity environmental tests. The EDC software features an intuitive interface, a powerful data review function and live data viewing. The combined EDM controller software provides one central location to set up parameters and a schedule between all three environments, with or without a connected controller. The powerful import and export features allow users to easily transfer test configurations between computers.

  • Syringe Pump

    500xv - Teledyne LABS

    The 500xv is able to pump higher viscosity material by reducing the restriction within the pump, specially designed with 3/8” ports at a 45 degree angle. Ball valves are used for automating refill and continuous flow which clear easily.​​The 500xv syringe pump provides precise delivery of high viscosity material up to 204 mL/min. Pulse-less flow is delivered up to 5,000 psi (345 bar) for pumping thick materials. Viscosity can be reduced by heating the pump chamber. A Temperature Control Jacket can be used to raise the temperature above ambient up to 100 ◦C.The High Temperature package allows the ability to heat up to 200 ◦C.The SyriXus controller has backlighted keypad and 4-line LCD display, as well as built-in and optional interfaces for computer control and other devices. Programming is easy and flexible, with instant access to menu screens even when the pump is running. This allows you to change operating parameters on the fly. Control the pump remotely using driver for LabVIEW™ software, in addition to pump controller.The 500xv pump module has a single-ratio drive train with auto-lubricating gears for long life and low maintenance. Special fittings are used to prevent leaks and ensure safety at maximum pressure.​

  • PLD Systems

    Pulsed Laser Deposition - Neocera, Inc.

    Is a versatile thin film deposition technique. A pulsed laser (~20 ns pulse width) rapidly evaporates a target material forming a thin film that retains target composition. This unique ability of stoichiometeric transfer of target composition into the film was realized first by the research team led by Dr. Venkatesan at Bell Communications Research, NJ, USA, nearly 30 years ago while depositing high temperature superconducting (YBa2Cu3O7) thin films. Since then, PLD has become the preferred deposition technique where ever thin films of complex material compositions are considered. Another unique feature of PLD is its ability for rapid prototyping of materials. The energy source (pulsed laser) being outside the deposition chamber, facilitates a large dynamic range of operating pressures (10-10 Torr to 500 Torr) during material synthesis. By controlling the deposition pressure and substrate temperature and using relatively small target sizes, a variety of atomically controlled nano-structures and interfaces can be prepared with unique functionalities.

  • Cytogenetic Drying Chamber

    CDS-5 - Thermotron Industries

    Developed in cooperation with Mayo Clinic, Thermotron's Cytogenetic Drying Chamberthe CDS-5was specifically designed for conducting cytogenetic slide drying tests during harvest of in situ and non-in situ grown cultures. The CDS-5 provides the optimum controlled temperature and humidity environment required to achieve ideal chromosome spreading results. As evidenced in research conducted by the Cytogenetics Laboratory at Mayo Clinic, the CDS-5 facilitates reliable and repeatable chromosome spreading. The use of an environmentally controlled drying chamber is a practical and cost effective way of achieving ideal chromosome spreading in a routine and highly consistent manner. Favorable chromosome spreading results can be obtained for both in situ and non-in situ cultures including PHA stimulated lymphocytes, bone marrow, amniocytes, and fibroblast.

  • Highly Accelerated Thermal Shock (HATS2™) Testing

    National Technical Systems

    NTS is the exclusive provider of HATS2™testing services in North America. Thermal shock testing has long been the accepted method to check robustness and reliability of plated-through holes and solder joint connections. Historically, thermal shock testing has been performed utilizing either dual chamber air-to-air systems or liquid-to-liquid systems. Both of these methods offer significant disadvantages in cost, time, and the fact that the samples must be transported between the hot and cold environments. Transportation of the samples between the temperature environments makes monitoring the resistance of the samples difficult and inaccurate due to the length and quantity of wires. The infrequent monitoring typically associated with traditional thermal shock methods also makes detection of “glitch” conditions marginal at best.